    Double layer custom constant temperature and humidity chamber

    如果您對(duì)該產(chǎn)品感興趣的話,可以
    產(chǎn)品名稱(chēng): Double layer custom constant temperature and humidity chamber
    產(chǎn)品型號(hào):
    產(chǎn)品展商: Lab Companion
    產(chǎn)品文檔: 無(wú)相關(guān)文檔

    簡(jiǎn)單介紹

    Double layer custom constant temperature and humidity chamber


    Double layer custom constant temperature and humidity chamber  的詳細(xì)介紹

    Double layer custom constant temperature and humidity chamber




    Temperature change rates from of 3, 5, 10, 15 or 18K/min.

    Advanced Reliability

    Lab Companion T/C series has a large tolerance for heat loads generated by the specimen, and achieves improved temperature change rate in an expanded temperature and humidity range.

    The new N-instrumentation allows AR series chambers to support an easy-to-use networking system.

    Two product types
    • Rapid-Rate Temperature Cycle Type
    • 6K/min per IEC 60068-3-5 (meeting the performance requirement of 5K/min. such as IEC 60068-2-14Nb.) NEW!
    • Standard Type

    The product lineup consists of 28 models that can be selected in accordance with temperature & humidity range, inside capacity and temperature change rate.

    Test Standard Conformance

    IEC 60068-2-1 : Cold

    IEC 60068-2-2 : Dry heat

    IEC 60068-2-14 Nb : Change of temperature with specified rate of change

    IEC 60068-2-30 : Damp heat, cyclic (Rapid-Rate Temperature Cycle Type)

    IEC 60068-2-38 : Composite temperature/ humidity cyclic test

    IEC 60068-2-78 : Damp heat, steady state

    ISO 16750-4(5.3) : Road vehicles, Temperature cycling tests

    Wide temperature range up to 200°C
    High temperature testing up to +200°C is possible (option).
    International safety standards
    Conforms to ISO12100 and IEC60204, IEC61000 and EN50581 to CE marking requirements based on EU directives: Low voltage directive, EMC directive, machinery directive, pressure equipment directive, and RoHS directive.


    Remote monitoring and control thanks to a web application
    No software required, an innovative web browser application allows to monitor and control the chamber with a computer via the chamber standard Ethernet/LAN port. Mobile PC, tablet, and smart phone with multiple chamber connections possible by wireless connection.
    Email alert
    When an alarm is triggered, an e-mail is sent to the registered PC or mobile address. A notification can also be sent at the time of test completion.
    Copy your test programs, output data on USB memory

    Without the need of a PC, copy and transfer your test profiles from one chamber to another. You can also download temperature and humidity data from the chamber for editing on your PC.



    Rapid-Rate Temperature Cycle Type New!

    Temperature & humidity range

    Minimum temp.: -70°C

    Maximum temp.: +180°C

    Humid.: 10 to 98%rh

    Temperature change rate

    Capacity 270L 480L 600L 800L 1000L
    Temp.range -45?+155°C
    Heat up
    Pull down
    10K/min.
    10K/min.
    18K/min.
    18K/min.
    10K/min.
    10K/min.
    15K/min.
    15K/min.
    6K/min.
    6K/min.
    10K/min.
    10K/min.
    15K/min.
    15K/min.
    6K/min.
    6K/min.

    * C: temperature & humidity, T: temperature only


    Totally frost-free
    Frosting will not appear on any part of the unit despite the temperature & humidity control range of range from 10 to 98%rh. Eradicating the need to remove frosting provides stable and continuous operations.
    Big tolerance for heat load
    Temperature only: up to 9000W
    Temp. & humid.: up to 550W
    Allowable heat load is different depends on models and operation conditions. Please refer to our brochure for the details.
    Energy-saving with Dual PID Control
    Dual PID Control (Proportional-Integral-Differential: control that enables the segmentation of refrigeration capacity) mostly controls only the refrigerator at 0°C or lower, thereby saving energy.
    Specimen temperature control (optional)
    Attaching a temperature measurement sensor to the specimen enables the temperature of the specimen to be monitored and controlled.
    Easy access to specimen
    Equipped with cable ports on both right & left sides as standard.
    Door notch port is also available to put cables through the door (option).
    N-instrumentation equipped with a color LCD touch panel
    Arge screen with LED backlight is clearer and provides faster display speed.
    -70 to +180°C (10 to 98%rh)
    Model Interior
    Volume
    Interior
    Dimensions
    (mm)
    Exterior
    Dimensions
    (mm)
    Performance
    Temp. & Humid. Temp. Only Time to Reach Extreme Temp. Temp. Change Rate per
    IEC 60068 3-5/ 3-6
    C/270/70/10 T/270/70/10 270L W580
    H750
    D615
    W895
    H1950
    D2080
    +20 → +180°C: 
    20 min.
    +20 → -70°C: 
    20 min.
    No
    Specimen
    -45 ? +155°C
    Heat-up Rate & 
    Pull-down Rate:
    10°C/min.
    C/270/70/15 T/270/70/15 +20 → +180°C: 
    15 min.
    +20 → -70°C: 
    15 min.
    No
    Specimen
    -45 ? +155°C
    Heat-up Rate & 
    Pull-down Rate:
    18°C/min.
    C/480/70/10 T/480/70/10 480L W800
    H950
    D650
    W1115
    H2090
    D2605
    +20 → +180°C: 
    20 min.
    +20 → -70°C: 
    20 min.
    No
    Specimen
    -45 ? +155°C
    Heat-up Rate & 
    Pull-down Rate:
    10°C/min.
    C/480/70/15 T/480/70/15 +20 → +180°C: 
    15 min.
    +20 → -70°C: 
    15 min.
    No
    Specimen
    -45 ? +155°C
    Heat-up Rate & 
    Pull-down Rate:
    15°C/min.
    C/800/70/10 T/800/70/10 800L W1000
    H980
    D800
    W1410
    H2085
    D2815
    +20 → +180°C: 
    20 min.
    +20 → -70°C: 
    20 min.
    No
    Specimen
    -45 ? +155°C
    Heat-up Rate & 
    Pull-down Rate:
    10°C/min.
    C/800/70/15 T/800/70/15 +20 → +180°C: 
    15 min.
    +20 → -70°C: 
    15 min.
    No
    Specimen
    -45 ? +155°C
    Heat-up Rate & 
    Pull-down Rate:
    15°C/min.
    C/600/70/5 T/600/70/5 600L W800
    H950
    D800
    W1115
    H1955
    D1855
    +20 → +180°C: 
    40 min.
    +20 → -70°C: 
    40 min.
    No
    Specimen
    -45 ? +155°C
    Heat-up Rate & 
    Pull-down Rate:
    6°C/min.
    C/1000/70/5 T/1000/70/5 1000L W1100
    H950
    D950
    W1415
    H2000
    D2030
    +20 → +180°C: 
    40 min.
    +20 → -70°C: 
    40 min.
    No
    Specimen
    -45 ? +155°C
    Heat-up Rate & 
    Pull-down Rate:
    6°C/min.